High concentrated etoposide solutions, additional physical stability data in dextrose 5%
  1. Marine Ravey1,
  2. Caroline Polo1,
  3. Elise D'Huart1,
  4. Jean Vigneron1,
  5. Béatrice Demoré1,2
  1. 1 Pharmacy, Centre Hospitalier Universitaire de Nancy, Vandoeuvre-lès-Nancy, France
  2. 2 Université de Lorraine, APEMAC, Vandoeuvre les Nancy, France
  1. Correspondence to Ms Marine Ravey, Pharmacy, Centre Hospitalier Universitaire de Nancy, Vandoeuvre-lès-Nancy, France; marine.ravey{at}hotmail.fr

Abstract

Objectives According to the manufacturers, the concentration of etoposide solutions should not exceed 0.4 mg/mL due to a risk of precipitation. Stability studies at higher concentrations were conducted and notably demonstrated 28 day stability up to 1.75 mg/mL for etoposide solutions in 5% dextrose (D5W). Nevertheless, colleagues report precipitation even at 0.4 mg/mL in their daily practice. The objective of this work was to reassess the physical stability of highly concentrated etoposide solutions in D5W (1.2 mg/mL), over a large number of preparations and under different manufacturing processes.

Methods To study the impact of manufacturing process, etoposide was taken with a spike or a needle and injected in three types of D5W containers (Easyflex, Viaflo and Ecoflac). Forty preparations were made for each container. For half of the preparations, a homogenisation was performed by a syringe rinse. Physical stability was realised by two examiners, with a visual examination searching for the appearance of a precipitate, daily during the first week, then twice a week until day 56.

Results Hundred and eighteen solutions were clear and colourless. Precipitates were observed for two solutions: one in an Easyflex bag on day 4 and one in an Ecoflac container on day 35.

Conclusions The physical stability at 1.2 mg/mL in D5W remains validated. Precipitations are rare and concern less than 2% of preparations. The appearance of a precipitate does not seem to be correlated to the kind of container or manufacturing process. A rinse was performed for these two solutions to assess a mechanical pressure effect more important on the solution, which could lead to a higher risk of precipitations. However, this is not observed in our daily practice, especially at lower concentrated solutions. We only recommend using an administration set with an in-line micro-filter as a precaution in case of precipitations.

  • medical oncology
  • pharmaceutical preparations
  • antineoplastic agents
  • pharmacy service
  • hospital
  • DRUG INCOMPATIBILITY

Data availability statement

All data relevant to the study are included in the article or uploaded as supplementary information.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Data availability statement

All data relevant to the study are included in the article or uploaded as supplementary information.