Table 2

Magnitude of error on paediatric and non-paediatric wards

Magnitude of errorAll reports n=1568Paediatric wards only n=491Non-paediatric wards/clinical settings n=1077
Overdose errors
 Greater than 1926 (59%)311 (63.3%)615 (57.1%)
 Greater than/equal to 10209100109
 Greater than/equal to 5293130163
 Greater than/equal to 2706250456
 Magnitude=1012759 (12%)68 (6.3%)
Underdose errors
 Less than 1464 (29.6%)128 (26.1%)336 (31.2%)
 Less than/equal to 0.536392271
 Less than/equal to 0.21275572
 Less than/equal to 0.1954055
 Magnitude 0.14616 (3.2%)30 (2.8%)
 Unknown178 (11.4%)52 (10.6%)126 (11.7%)